Class Name: Display type of device and this property is read-only,
Audio Library Version: Display the audio library version used in the selected device. You can change the audio library version. On the property panel, click on the audio library version, select the desired audio library version, and click save.
If a device has a signal flow with audio objects created in an older version, compatible audio objects will upgrade automatically. Non-compatible audio objects in Signal Flow Designer will be highlighted in blue or displayed as a warning in the compiler; these audio objects can be upgraded using the audio object context menu.In the following cases device association with a dll cannot be changed.
If a device’s signal flow is open.
If you have a monitoring window open, such as a streaming or profiler window.
A change in dll association for one device has no effect on other device instances.
Device Id: Enter the ID of the selected device. Make sure the device ID should be unique.
Node Address: The Node address of the selected device. Each device has a unique node address assigned to it.
Name: Name of the device.
MaxTuningDataSize: Maximum tuning data.
System Context: Set the system context Init or Runtime.